UBX-025HMD065 Flow Monitor | Senseca UBX-025

Availability:

5 in stock


Senseca UBX-025 paddle flow monitor, model UBX-025HMD065. DN 65 pipe; R 1 inch insertion thread; Brass; double changeover contact. Water switching point (decreasing flow): 6.0 ± 2.0 m³/h; Qmax: 33 m³/h.
🚚 READY STOCK AVAILABLE
📞 9611145044
✉ spectanetindia@gmail.com

UBX-025HMD065 Senseca UBX-025 Flow Monitor

The UBX-025HMD065 is a mechanical paddle-type flow monitor for checking flow or no-flow conditions in liquid pipelines. A metal-bellows-supported paddle directly actuates a microswitch. The switching point is factory-set for the specified nominal pipe diameter.

Key Features

  • Nominal pipe size: DN 65
  • Process connection: R 1 inch insertion thread
  • Wetted-body material: Brass
  • Contact configuration: Double changeover contact
  • Factory-set water switching point for decreasing flow: 6.0 ± 2.0 m³/h
  • Recommended maximum flow (Qmax): 33 m³/h for water at approximately 2 m/s
  • Gold-contact microswitch
  • Pressure resistance: PN 16
  • Ingress protection: IP65 / IP67 when using an approved connection cable

Technical Specifications

  • Product family: Senseca UBX-025
  • Nominal diameter: DN 65
  • Reference pipe outside diameter for factory calibration: 76.1 mm
  • Reference pipe wall thickness: 2.9 mm
  • Media: water, mineral oil, silicone oil and ester oil; confirm suitability for the actual fluid
  • Medium temperature: -40 to +140 °C; no superheated steam
  • Ambient temperature: -40 to +90 °C
  • Electrical connection: M16 × 1.5 cable gland for 7–11 mm cable; DIN 43650-A and Harting plug options listed
  • Electrical ratings depend on load: up to 250 V AC/DC, 6 A for ohmic loads; observe lower inductive-load limits and use suitable protective circuitry
  • Switch housing: die-cast aluminium
  • Weight: approximately 1.3 kg

Applications

For industrial liquid-flow monitoring, flow proving and equipment protection where a defined flow/no-flow signal is required. Confirm compatibility and switching point before ordering.

Installation and Ordering Notes

  • Standard mounting is for horizontal flow. Mounting orientation affects the switching point and range.
  • Provide a straight calming section of 10 × DN at the inlet and outlet.
  • Use standard pipe wall thickness according to DIN 2448 for conditions matching factory calibration.
  • Install a filter where the medium may contain contaminants.
  • The switching point is factory-set for a defined pipe size and secured; specify pipe diameter, flow direction, medium and required switching point when ordering.
  • Process gasket is not included in the scope of supply.
  • For mineral oils, switching values and Qmax depend on viscosity; provide oil type/viscosity and temperature.

Contact Spectanet for availability, pricing and assistance selecting the correct UBX-025 configuration.